top of page
ata-resim-2.jpg
blog.jpg

YAPMIŞ OLDUĞU BİRKAÇ DONANIM TASARIM:

REFERENCE PROJECTS:

General-purpose IP-based control system design

(Design of Main Board and Power Board and Connector Boards).

  • MIL-STD-810F

  • MIL-STD-461F

  • MIL-STD-1275D

  • MIL-STD-464C

  • System Design

  • Block Diagrams

  • PCB design(16 Layer/Analog/Digital/Power signals)

  • 0.5mm BGA package PCB design

  • 2mm PCB thickness

  • Use of 0.65mm and 1mm BGA MCU (STM32F7 and STM32F4 series)

  • Use of 0.5mm BGA FPGA (Xilinx Spartan7 series)

  • Power management, Super Capacitor

  • Isolated ports and isolated power supply

  • RS232, RS485, I2C, I2S, SPI, UART, USB, Ethernet, CAN BUS, Clock, Audio signalsAnalog/digital Sensor signals, LVDS (Low-Voltage Differential Signaling), Analog signals, 1-Wire signals, use of parallel interfaces

  • Isolated CAN BUS usage, isolated RS485 usage, isolated USB usage, Transformer shielding, Ethernet Phyter transformer,  other signals requiring isolation

  • Flash memory, CODEC, Temperature Sensor, uSD Card, JTAG, Serial port, Audio circuits, Gyroscope usage

  • Circuit simulaiton (PSPICE, LT Spice and NI Multisim)

Half brick DC/DC Module Design (Po=150W, Input Voltage 9-75 VDC)

 

  • Half Brick DC-DC Module

  • 8:1 Input voltage range (9-75VDC)

  • 150W İsolated output

  • Efficiency up to 90%

  • Fixed Switching Frequency

  • UVLO Input Voltage Protection

  • Over Temperature Protection

  • Over Voltage / Current Protection

  • Remote On/Off

  • Industry Standard Half Brick Pack (Half Brick)

  • Fully Isolated 1500VDC

  • Conforms to UL60950-1 2 Standard

  • COTS can be used as a product.

  • Ease of use with MIL-STD-1275

  • Ease of use with MIL-STD-704

Active EMI Filter (AEF) Design

  • Active EMI filter module design

  • MIL-STD-461 (CE101, CE102)

  • 25dB/uV EMI damping

  • Circuit simulaiton (LT Spice and NI Multisim)

Laser Warning System Design

  • MIL-STD-810F

  • MIL-STD-461F

  • MIL-STD-1275D

  • MIL-STD-464C

  • System Design

  • Block Diagrams

  • Dark side photodiode sensor usage

  • DC-DC converter design with -100VDC, -450VDC, -55VDC output voltage.

  • TIA (Transimpedance amplifier design)

  • Filter design and simulation in high impedance TIA circuits(Band Pass Filter, Low pass Filter, High Pass Filter).

  • Circuit simulaiton (LT Spice and NI Multisim)

Design of remote data collection and cloud storage system for wind turbines

  • Detection of different sensors

  • Data Acquisition Card

  • IEC 61850 communication

  • USING AS A POWER OVER BUS (FOR RS485)

FADEC (Full Authority Digital Engine Control)

  • Power supply management

  • Boost converter design for injection

  • Motor Control Circuit Design

  • ECU (Electronic Control Unit)

  • Relay Unit

  • PSPICE Simulation

  • Filter Cards (MIL-DTL-38999 connectors)

  • Peak and hold type injector driver

  • H-Bridge driver

  • RTCA/DO-160

  • MIL-STD-461

  • MIL-STD-810

Military Intercom System

  • PoE (Power Over Ethernet) designing

  • Power supply designing (Central Unit )

  • Power supply designing (System Unit-1 )

  • Power supply designing (System Unit-2 )

  • Handheld Controller (Tablet PC without battery) PCB designing

  • Hot-swap controller usage

  • MIL-STD-461

  • MIL-STD-1275

  • MIL-STD-810

Design of Hand-held Military Computer motherboard and power card

  • MIL-STD-461

  • MIL-STD-1275

  • MIL-STD-810

  • Two-battery automatic charging system

  • PCB design(10 Layer/Analog/Digital/Power signals)

  • System Design

  • Block Diagrams

  • 2mm PCB thickness

Smart Battery Charger Unit​ for Hand-held Military Computer

  • MIL-STD-1275

  • Military battery working conditions

  • Two-battery automatic charging system

  • PCB design(4 Layer/Analog/Digital/Power signals)

  • Use of STM32F103

  • 1.6mm PCB thickness

Military Ship Alarm&Anouncement Power Supply

(TCG Anadolu Project: The design and military tests of the Alarm & Announcement System of the Turkish Battleship (TCG Anadolu) and the main power unit of our PBX operating the system)

  • Redundant using

  • Hot-plug design

  • 1.5kW + 1.5kW=3kW output power

  • Use of Hold-up capacitor block

  • MIL-STD-810G

  • MIL-STD-461F

Military Submarine Alarm&Anouncement Power Supply

(Submarine Project: The design and military tests of the Alarm & Announcement System of the Turkish Submarine and the main power unit of our PBX operating the system)

  • Redundant using

  • Hot-plug design

  • 1.5kW + 1.5kW=3kW output power

  • Use of Hold-up capacitor block

  • Lead-acid battery charge unit design

  • MIL-STD-810G

  • MIL-STD-461F

GPS / INS guided ammunition main power unit design

  • Redundancy

  • Use of Hold-up capacitor block

  • Mil-STD-1553 signal

  • RTCA / DO-160 Protection

  • DO-160

  • Compliance with MIL-STD-704A/B/C/D/E/F support (All of them -A/B/C/D/E/F-)

  • MIL-HDBK-704-8

Military internal communication system power circuits design

(Milgem Project: The design and military tests of the Alarm & Announcement System of the Turkish Battleship (Milgem) and the main power unit of our PBX operating the system)

  • Redundancy

  • A very discrete telecom dc-dc switcher design

  • System Design

  • MIL-STD-810G

  • MIL-STD-461F

  • MIL-STD-1275

1kW different power units design for military ships

  • MIL-STD-461

  • MIL-STD-1399 (For Navy)

  • MIL-STD-810

200W led power supply design

  • IEC 60950(EN 60950)

  • IEC 61000-X-X (EN 61000-X-X)

  • IEC 55022 (EN 55022)

Discrete Industrial and Telecom power supply(DC-DC / AC-DC) design between 6w-600w

  • IEC 60950(EN 60950)

  • IEC/EN  62368-1

  • IEC 61000-X-X (EN 61000-X-X)

  • IEC 55022 (EN 55022)

  • IEC 55032 (EN 55032)

  • IEC 55011 (EN 55011)

  • IEC 55024 (EN 55024)

Assorted military and commercial backplane PCB cards design (Power and signals)

Many large and small DC-DC, AC-DC, PFC power supply card designs

Designing and verifying AC-DC&-48VDC and DC-DC&-48VDC isolated&non-isolated Telecom power supplies

BLOG' da yer almasını istediğiniz yazılar için üye olup email atabilirsiniz...

                                           info@ahmetturanalgin.com

Feragatname:

Bu yazıda ve "www.ahmetturanalgin.com" web sitesi üzerinde verilen tüm bilgiler, Firmalar' a "Eğitim" ve "Danışmanlık" hizmetleri içeriğiyle aktarılan tüm bilgiler, 29 yıllık mühendislik tecrübeleriyle verilen bilgilerdir. Verilen tüm bilgilerin doğru ve güvenilir olduğuna inanılmaktadır.

 

Ancak; "Ahmet Turan Algın" veya "www.ahmetturanalgin.com" bu tür bilgilerin kullanımından doğabilecek herhangi bir patent veya üçüncü şahısların haklarının ihlalinden sorumlu değildir. 

 

"Ahmet Turan Algın" veya "www.ahmetturanalgin.com" dan herhangi bir patent veya patent hakkı kapsamında dolaylı veya başka bir şekilde lisans verilmez.

 

Firmalar' a "Eğitim" ve "Danışmanlık" hizmetleri içeriğiyle aktarılan tüm bilgiler ve bu web sitesinde belirtilen özellikler, önceden haber verilmeksizin değiştirilebilir. Bu özellikler, daha önce sağlanan tüm bilgilerin yerine geçer ve onların yerini alır.

 

Firmalar' a "Eğitim" ve "Danışmanlık" hizmetleri içeriğiyle aktarılan tüm bilgiler ve "Ahmet Turan Algın" veya "www.ahmetturanalgin.com" da yayınlanan makalelerin içeriğinde yer alan teknik bilgilerin, "Ahmet Turan Algın" veya "www.ahmetturanalgin.com" un açık yazılı onayı olmadan, insan hayatını etkileyen projelerde, yaşam destek cihazlarında veya sistemlerinde, kritik bileşenler olarak kullanılmasına izin verilmez. Kullanılması durumunda; "Ahmet Turan Algın" veya "www.ahmetturanalgin.com" hiçbir şekilde sorumlu tutulamaz.

BU WEB SİTESİ ÜZERİNDEN SAĞLANAN TÜM BİLGİLER, FİRMALAR' A "EĞİTİM" VE "DANIŞMANLIK" HİZMETLERİ İÇERİĞİYLE AKTARILAN TÜM BİLGİLER, YALNIZCA BİLGİLENDİRME AMACI İÇİNDİR.

 

"AHMET TURAN ALGIN" VEYA "www.ahmetturanalgin.com"; FİRMALAR' A "EĞİTİM" VE "DANIŞMANLIK" HİZMETLERİ İÇERİĞİYLE AKTARILAN TÜM BİLGİLER VE BU SİTEDE YER ALAN BİLGİLERİN HERHANGİ BİR AMACA UYGUNLUĞU İLE İLGİLİ OLARAK,  HİÇBİR BEYANDA (TAAHHÜTTE) BULUNMAMAKTADIR. BURADA BİLGİ, HERHANGİ BİR GARANTİ OLMAKSIZIN "OLDUĞU GİBİ" SAĞLANIR. BU WEB SİTESİ ÜZERİNDEN SAĞLANAN TÜM BİLGİLERDE, FİRMALAR' A "EĞİTİM" VE "DANIŞMANLIK" HİZMETLERİ İÇERİĞİYLE AKTARILAN TÜM BİLGİLERDE, KULLANILAN ÇİZİM VE/VEYA RESİMLER TEMSİLİ OLARAK VERİLMİŞTİR.

 

Telif hakkı:

© 2020-2024 arasında yazılan Ahmet Turan ALGIN'ın Tasarım Notları ve Makaleleri; bu BLOG' un, bu FORUM' un ve web sitesinin yazarından ve / veya sahibinden açık ve yazılı izin alınmadan bu web sitesinde yer alan materyal ve/veya materyallerin izinsiz kullanımı ve / veya çoğaltılması kesinlikle yasaktır.

Herhangi bir biçimde veya herhangi bir yolla (elektronik, mekanik, fotokopi, kayıt veya başka türlü) kopyalanamaz, çoğaltılamaz, iletilemez veya depolanamaz.

Ahmet Turan ALGIN'ın Tasarım Notları ve Makalelerine, orijinal içeriğe uygun ve belirli bir yön vererek tam ve net bir şekilde atıfta bulunulması koşuluyla alıntılar ve bağlantılar kullanılabilir.

<script src="https://platform.linkedin.com/badges/js/profile.js" async defer type="text/javascript"></script>

<div class="badge-base LI-profile-badge" data-locale="en_US" data-size="medium" data-theme="dark" data-type="VERTICAL" data-vanity="ahmet-turan-algin-08253524" data-version="v1"><a class="badge-base__link LI-simple-link" href="https://tr.linkedin.com/in/ahmet-turan-algin-08253524?trk=profile-badge">Ahmet Turan ALGIN</a></div>

 

2024 / Ahmet Turan ALGIN © Tüm hakları saklıdır.

 

bottom of page